products
PRODUCTS DETAILS
Home > Products >
XL6A Tabletop Low Speed Centrifuge PRP PRF CGF For Medical Blood Centrifuge

XL6A Tabletop Low Speed Centrifuge PRP PRF CGF For Medical Blood Centrifuge

MOQ: 1PC
Price: US$299/pc
Standard Packaging: by carton
Delivery Period: 5 working days
Payment Method: L/C, D/A, D/P, T/T, Western Union
Supply Capacity: 500pcs/monthly
Detail Information
Place of Origin
CHINA
Brand Name
CENLEE
Certification
CE
Model Number
XL6A
Minimum Order Quantity:
1PC
Price:
US$299/pc
Packaging Details:
by carton
Delivery Time:
5 working days
Payment Terms:
L/C, D/A, D/P, T/T, Western Union
Supply Ability:
500pcs/monthly
Highlight:

Tabletop Low Speed Centrifuge

,

PRP Medical Blood Centrifuge

,

CGF Low Speed Centrifuge

Product Description

XL6A Tabletop Low Speed Centrifuge PRP PRF CGF For Medical Use Blood Centrifuge

 

 

Features:

  1. Microcomputer control, driven by a brushless DC motor, runs smoothly, with low noise and a strong experience
  2. The appearance is simple, the curve is beautiful, it adopts a special shock absorption system, and has an automatic balance function
  3. rapid switching among different function PRP/APRF/PRF/CGF, easy to operation
  4. Equipped with various protection functions such as over-speed, instantaneous centrifugation and continuous centrifugation methods, automatic fault alarm function, safe and reliable
  5. Air-cooled centrifuge, effectively reducing the temperature rise during the centrifugation process
  6. Full countdown display during operation, real-time display of remaining time

 

Technical Parameter

Model XL6A Timing range 0-99min
Maximum speed 4000r/min Power supply AC 220V 50Hz 5A
Maximum RCF 2200×g Machine noise ≤58dB(A)
Maximum capacity 8*10ml Power 100W
Speed Accuracy ±20r/min Dimensions 255×310×200mm
Motor drive DC brushless Weight 7.0kg

 

CGF Application:

The CGF program is designed for dentistry, applied in implantology, periodontology, maxillofacial surgery, apical surgery, etc., such as GBR, maxillary sinus lift, peri-implantitis, immediate implantation, rapid regeneration after tooth extraction, site preservation, aesthetic area implantation, frontal sinus membrane repair, replacement of absorbable bone membrane, ect

XL6A Tabletop Low Speed Centrifuge PRP PRF CGF For Medical Blood Centrifuge 0

 

Precautions for the preparation and use of CGF/PRP | CGF/ PRP

  1. Ensure that the indoor operating temperature is between 20 30 degrees Celsius; the centrifuge needs to be placed on a stable table , no shaking
  2. Check the centrifuge rotor and related tools, ensure that the tools have been sterilized
  3. Use a dedicated blood collection tube with no additives, and confirm the packaging seal and within validate
  4. During the blood collection process, the blood collection needle should be inserted into the blood vessel first, and the other end should be inserted obliquely into the blood collection tube, ensuring that the blood flows slowly into the interior along the tube wall.
  5. After blood collection is completed, gently shake the blood collection tube 2-3 times and prepare immediately; the blood collection tube should be placed symmetrically in the centrifuge rotor, and ensure that it is inside the tube holder completely
  6. Choose the centrifugation mode according to the actual case needs, do not forcibly open the cabin door before the centrifugation ends
  7. After centrifugation is completed, do not shake the blood collection tube, and make a membrane or other treatment as needed according to the case.
  8. When making a film in oral clinical (CGF), you can use the self-weight of the counterweight plate to press for 1-2 minutes, no need to press with your hands |
  9. When mixing bone powder in oral clinical (CGF), if there is too much serum, you can use sterile gauze to absorb it (please add an appropriate amount of fibrin, too much fibrin may make the bone powder viscous block form slower)
  10. For the maintenance of the centrifuge, you can use alcohol to wipe it. If conditions allow, you can also use ultraviolet light for disinfection.

 

PRP Preparation Process

  1. Draw venous blood with a vacuum blood collection tube
  2. Centrifuge with a centrifuge to generate PRP
  3. Extract PRP
  4. Fill the surgical area
  5. XL6A Tabletop Low Speed Centrifuge PRP PRF CGF For Medical Blood Centrifuge 1
products
PRODUCTS DETAILS
XL6A Tabletop Low Speed Centrifuge PRP PRF CGF For Medical Blood Centrifuge
MOQ: 1PC
Price: US$299/pc
Standard Packaging: by carton
Delivery Period: 5 working days
Payment Method: L/C, D/A, D/P, T/T, Western Union
Supply Capacity: 500pcs/monthly
Detail Information
Place of Origin
CHINA
Brand Name
CENLEE
Certification
CE
Model Number
XL6A
Minimum Order Quantity:
1PC
Price:
US$299/pc
Packaging Details:
by carton
Delivery Time:
5 working days
Payment Terms:
L/C, D/A, D/P, T/T, Western Union
Supply Ability:
500pcs/monthly
Highlight

Tabletop Low Speed Centrifuge

,

PRP Medical Blood Centrifuge

,

CGF Low Speed Centrifuge

Product Description

XL6A Tabletop Low Speed Centrifuge PRP PRF CGF For Medical Use Blood Centrifuge

 

 

Features:

  1. Microcomputer control, driven by a brushless DC motor, runs smoothly, with low noise and a strong experience
  2. The appearance is simple, the curve is beautiful, it adopts a special shock absorption system, and has an automatic balance function
  3. rapid switching among different function PRP/APRF/PRF/CGF, easy to operation
  4. Equipped with various protection functions such as over-speed, instantaneous centrifugation and continuous centrifugation methods, automatic fault alarm function, safe and reliable
  5. Air-cooled centrifuge, effectively reducing the temperature rise during the centrifugation process
  6. Full countdown display during operation, real-time display of remaining time

 

Technical Parameter

Model XL6A Timing range 0-99min
Maximum speed 4000r/min Power supply AC 220V 50Hz 5A
Maximum RCF 2200×g Machine noise ≤58dB(A)
Maximum capacity 8*10ml Power 100W
Speed Accuracy ±20r/min Dimensions 255×310×200mm
Motor drive DC brushless Weight 7.0kg

 

CGF Application:

The CGF program is designed for dentistry, applied in implantology, periodontology, maxillofacial surgery, apical surgery, etc., such as GBR, maxillary sinus lift, peri-implantitis, immediate implantation, rapid regeneration after tooth extraction, site preservation, aesthetic area implantation, frontal sinus membrane repair, replacement of absorbable bone membrane, ect

XL6A Tabletop Low Speed Centrifuge PRP PRF CGF For Medical Blood Centrifuge 0

 

Precautions for the preparation and use of CGF/PRP | CGF/ PRP

  1. Ensure that the indoor operating temperature is between 20 30 degrees Celsius; the centrifuge needs to be placed on a stable table , no shaking
  2. Check the centrifuge rotor and related tools, ensure that the tools have been sterilized
  3. Use a dedicated blood collection tube with no additives, and confirm the packaging seal and within validate
  4. During the blood collection process, the blood collection needle should be inserted into the blood vessel first, and the other end should be inserted obliquely into the blood collection tube, ensuring that the blood flows slowly into the interior along the tube wall.
  5. After blood collection is completed, gently shake the blood collection tube 2-3 times and prepare immediately; the blood collection tube should be placed symmetrically in the centrifuge rotor, and ensure that it is inside the tube holder completely
  6. Choose the centrifugation mode according to the actual case needs, do not forcibly open the cabin door before the centrifugation ends
  7. After centrifugation is completed, do not shake the blood collection tube, and make a membrane or other treatment as needed according to the case.
  8. When making a film in oral clinical (CGF), you can use the self-weight of the counterweight plate to press for 1-2 minutes, no need to press with your hands |
  9. When mixing bone powder in oral clinical (CGF), if there is too much serum, you can use sterile gauze to absorb it (please add an appropriate amount of fibrin, too much fibrin may make the bone powder viscous block form slower)
  10. For the maintenance of the centrifuge, you can use alcohol to wipe it. If conditions allow, you can also use ultraviolet light for disinfection.

 

PRP Preparation Process

  1. Draw venous blood with a vacuum blood collection tube
  2. Centrifuge with a centrifuge to generate PRP
  3. Extract PRP
  4. Fill the surgical area
  5. XL6A Tabletop Low Speed Centrifuge PRP PRF CGF For Medical Blood Centrifuge 1
Sitemap |  Privacy Policy | China Good Quality PRP Centrifuges Supplier. Copyright © 2021-2025 prpcentrifuges.com . All Rights Reserved.